LEX25
LEX25 Ex ia/ib certified resistance thermometer for zone 0, 1 and 2
Specifications
ATEX execution | II 1 G Ex ia IIC T6...T1 Ga |
II 1/2 G Ex ia/ib IIC T6...T1 Ga/Gb | |
II 2 G Ex ib IIC T6...T1 Gb | |
ATEX certificate | DEKRA 17ATEX0123 X |
IECEx execution | Ex ia IIC T6...T1 Ga |
Ex ia/ib IIC T6...T1 Ga/Gb | |
Ex ib IIC T6...T1 Gb | |
IECEx certificate | IECEx DEK 17.0046X |
Suitable for zone | 0, 1 and 2 |
Ingress protection | lP65 / IEC529 |
Ambient temp. range | -45°C...+80°C, this can be limited depending on the materials applied such as cables, connection heads, junction boxes and transmitters. |
Construction | Mineral insulated (MgO) |
Material | SS316 standard, other materials possible |
Diameter | Customer to specify (0.25-12.7mm) |
Length | Customer to specify |
Execution | Single or Duplex Pt100 |
Connection | 3-wire standard, 4-wire optional |
Accuracy | According IEC 60751 Cl. B, A or AA |
Measuring range | -20°C...+400°C standard, -220°C...+600°C optional |
Length | 45mm |
Diameter | To suit cable diameter |
Cable insulation | PVC, PUR, Silicon or PTFE. Customer to specify |
Cable length | Customer to specify |
Customisation possibilities
You can remark the customisation in your quote
Productcode | LEX25 |
---|---|
Sensor S or D | … |
Connection 3- or 4-wire | … |
Class B, A or AA | … |
Diameter | … |
Length "L" in mm | … |
Length "K" in mm | … |