CA 2003
CA 2003 Resistance thermometer
Specifications
| Construction | Closed-end tube |
| Diameter | 9.0mm standard, other diameters possible |
| Material | SS 316 - (Wst 1.4401) standard, other materials possible |
| Insertion length | Customer to specify |
| Process connection | 1/2"BSP (G1/2") standard, M20x1.5, 1/2"NPT or other threads possible |
| Extension length | Customer to specify |
| Material | Aluminium, plastic or stainless steel |
| Cable entry | M20x1.5 cable gland standard, other threads possible |
| Type | MI 2025 |
| Construction | Replaceable springloaded, 6mm standard, other diameters possible |
| Length | E = L + X + 35 mm |
| Material | SS 316 - (Wst 1.4401) standard, other materials possible |
| Single or Duplex Pt100 | |
| Accuracy | According IEC 60751 Cl. B, A or AA |
| Style / Connection | 3-wire system standard, 4-wire system optional |
| Range | -20 / +400°C standard, -220 / +600°C optional |
| Transmitter 4-20mA | In-Head Transmitter, standard or Explosion proof. Please select from our standard range, see |
| Swing-Cover head | DAN transmitter direct mounted on measuring insert |
| High Swing-Cover head | DAN-H, transmitter in cover, insert with ceramic block |
Customisation possibilities
You can remark the customisation in your quote
| Productcode | CA 2003 |
|---|---|
| Sensor (S or D) | … |
| Connection 3- or 4-wire | … |
| Class B, A or AA | … |
| Length "L" in mm | … |
| Length "X" in mm | … |
| Diameter "D" in mm | … |