TF 5840
TF 5840 Bayonet type thermocouple
Specifications
Insertion length | Springloaded, fixed pressure |
Diameter | 5.0mm standard, other diameters possible |
Length L1 x L2 | Code A : L1 = 70, L2 = 20 Code B : L1 = 95, L2 = 45 |
Spring | Diameter 7.0mm, springloading action |
Bayonet | Diameter 12.2mm, one slot |
Glassfiber insulated thermocouple cable with steelwire braiding | |
Length | 3000mm standard, other lengths possible |
Calibration | K, J or L |
For duplex | KK, JJ or LL |
Accuracy | According IEC 60584 / DIN 43710 |
Temperature | 400°C maximum |
Hot junction | Grounded |
Model B1 | Process connection 1/4"BSP (G1/4") |
Model B2 | Process connection 3/8"BSP (G3/8") |
Model B3 | Process connection M14x1.5 |
Please order separately |
Customisation possibilities
You can remark the customisation in your quote
Productcode | TF 5840 |
---|---|
Calibration | … |
Length "K" in mm | … |
Code A or B | … |