LEX55
                        
                    
                LEX55 Ex ec certified RTD sensor with transmitter for zone 2 and 22
Specifications
| ATEX execution | II 3 G Ex ec IIC T6...T1 Gc | 
| ATEX certificate | DEKRA 18ATEX0024 X | 
| IECEx execution | Ex ec IIC T6...T1 Gc | 
| IECEx certificate | IECEX DEK 17.0046X | 
| Suitable for zone | 2 and 22 | 
| Ingress protection | IP65 / IEC529 | 
| Ambient temp. range | -45°C...+80°C, this can be limited depending on the materials applied such as cables, connection heads, junction boxes and transmitters. | 
| Model | DAN-AK (showed), other Ex ec certified heads possible | 
| Material | Aluminium, plastic or stainless steel | 
| Cable Entry | M20x1.5 standard, other threads possible | 
| Model | Select from our standard range or specify your standardized brand | 
| Range | Customer to specify | 
| Head mounted | Standard mounted on insert, replaces the terminal block | 
| Alternative mounting | Mounted in the cover of the head | 
| Construction | Springloaded and replaceable | 
| Springaction | >10mm standard, >40mm optional | 
| Diameter | 6.0mm standard, other diameters possible | 
| Type | Mineral insulated (MgO) | 
| Execution | Single or Duplex Pt100 | 
| Connection | 3-wire standard, 4-wire optional | 
| Accuracy | According IEC 60751 Cl. B, A or AA | 
| Measuring range | -20°C...+400°C standard, -220°C...+600°C optional | 
| Type | Nipple - Union -nipple standard, other constructions possible | 
| Material | Stainless Steel | 
| Style / Connection | 1/2"NPT standard, other threads possible | 
| The LEX55 is the replacement for the LEX45 Ex nA | |
| This datasheet is purely indicative, build-up of model code may vary from this datasheet | 
Customisation possibilities
You can remark the customisation in your quote
| Productcode | LEX55 | 
|---|---|
| Sensor S or D | … | 
| Class B, A or AA | … | 
| Length "U" in mm | … | 
| Length "X" in mm | … | 
| Transmitter model | … | 
 
                    