LEX25
                        
                    
                LEX25 Ex ia/ib certified thermocouple for zone 0, 1 and 2
Specifications
| ATEX execution | II 1 G Ex ia IIC T6...T1 Ga | 
| II 1/2 G Ex ia/ib IIC T6...T1 Ga/Gb | |
| II 2 G Ex ib IIC T6...T1 Gb | |
| ATEX certificate | DEKRA 17ATEX0123 X | 
| IECEx execution | Ex ia IIC T6...T1 Ga | 
| Ex ia/ib IIC T6...T1 Ga/Gb | |
| Ex ib IIC T6...T1 GB | |
| IECEx certificate | IECEx DEK 17.0046X | 
| Suitable for zone | 0, 1 and 2 | 
| Ingress protection | IP65 / IEC529 | 
| Ambient temp. range | -45°C...+80°C, this can be limited depending on the materials applied such as cables, connection heads, junction boxes and transmitters. | 
| Model | CE (showed), other connectionheads possible | 
| Material | Aluminium, plastic or stainless steel | 
| Cable entry | M20x1.5 standard, other threads possible | 
| Construction | Springloaded and replaceable | 
| Springaction | >10mm standard, >40mm optional | 
| Diameter | 6.0mm standard, other diameters possible | 
| Type | Mineral insulated (MgO) | 
| Calibration | K, T, J, E, N, R, S, B, U or L | 
| For duplex | KK, TT, JJ, EE, NN, RR, SS, BB, UU or LL | 
| Accuracy | According to IEC 60584-1 | 
| Type | Nipple - union - nipple standard, other constructions possible | 
| Material | Stainless Steel | 
| Style / Connection | 1/2"NPT standard, other threads possible | 
| Length | 150mm standard, other lengths possible | 
| This datasheet is purely indicative, build-up of model code may vary from this datasheet depending on chosen model or execution! | 
Customisation possibilities
You can remark the customisation in your quote
| Productcode | LEX25 | 
|---|---|
| Thermocouple calibration | … | 
| Colour code | … | 
| Diameter "D" in mm | … | 
| Length "U" in mm | … | 
| Length "X" in mm | … | 
 
                    