Specifications

ATEX executionII 3 G Ex ec IIC T6...T1 Gc
ATEX certificateDEKRA 18ATEX0024 X
IECEx executionEx ec IIC T6...T1 Gc
IECEx certificateIECEx DEK 17.0046X
Suitable for zone2 and 22
Ingress protectionIP65 / IEC529
Ambient temp. range-45°C...+80°C, this can be limited depending on the materials applied such as cables, connection heads, junction boxes and transmitters.
ModelDAN-AK (showed), other Ex certified connectionheads possible
MaterialAluminium, Stainless Steel or Plastic
Cable entryM20x1.5 standard, other threads possible
ModelSelect from our standard range or specify your standardized brand
Range and modelTo specify
Head mountedStandard mounted on insert, replaces the terminal block
Alternative mountingMounted in the cover of the head
ConstructionSpringloaded and replaceable
TypeMineral insulated (MgO)
Diameter6.0mm standard, other diameters possible
CalibrationK, T, J, E, R, S, B, U, N or L
For duplexKK, TT, JJ, EE, RR, SS, BB, UU, NN or LL
AccuracyAccording to IEC 60584-1
TypeNipple - union - nipple standard, other constructions possible
MaterialStainless Steel
Style / Connection1/2"NPT
Length150mm standard, other lengths possible
Springaction>10mm standard, >40mm optional
This datasheet is purely indicative, build-up of model code may vary from this datasheet
The LEX55 is the replacement for the LEX45 Ex nA

Customisation possibilities

You can remark the customisation in your quote

Productcode LEX55
Thermocouple calibration
Colourcode
Diameter "D" in mm
Length "U" in mm
Length "X" in mm
Transmitter model Customer to specify