LEX15

LEX15 Ex e certified resistance thermometer with connectionhead for zone 1 and 2

Datasheet View catalog

Specifications

ATEX executionll 2 G Ex eb llC T6...T1 Gb
ATEX certificateDEKRA 17ATEX0123 X
IECEx executionEx eb IIC T6...T1 Gb
IECEx certificateIECEx DEK 17.0046X
Suitable for zone1 and 2
Ingress protectionIP65 / IEC529
Ambient temp. range-45°C...+80°C, this can be limited depending on the materials applied such as cable, connection head or junction box.
ModelDAN-AK (showed), other Ex e certified heads possible
MaterialAluminium, plastic or stainless steel
Cable entryM20x1.5 standard, other threads possible
ConstructionSpringloaded and replaceable
Spring action>10mm standard, >40mm optional
Diameter6.0mm standard, other diameters possible
TypeMineral insulated (MgO)
ExecutionSingle or Duplex Pt100
Connection3-wire standard, 4-wire optional
AccuracyAccording IEC 60751 Cl. B, A or AA
Measuring range-20°C...+400°C standard, -220°C...+600°C optional
TypeNipple - Union -nipple standard, other constructions possible
MaterialStainless steel
Style / Connection1/2"NPT standard, other threads possible
Length150mm standard, other lengths possible

Customisation possibilities

You can remark the customisation in your quote

Productcode LEX15
Sensor S or D
Connection 3- or 4-wire
Class B, A or AA
Diameter "D" in mm
Length "U" in mm
Length "X" in mm