Exi Infrared sensors
Specifications
The ExTemp’s IIC T4, IIIC T135°C, ATEX and IECEx rating makes it suitable for many applications in hazardous areas, including: | |
Petrochemical - condition monitoring, Petrochemical - liquid storage and processing, Paper, Coal conveyors, Gas cylinder filling, Automotive painting or Offshore | |
ATEX Classification | Ex II 1GD |
ATEX Certificate | CML 14ATEX2079 |
IECEx Classification (Gas) | Ex ia IIC T4 Ga |
IECEx Classification (Dust) | Ex ia IIIC T135°C IP65 Da |
IECEx Certificate | IECEx CML 14.0032 |
Ambient temperature rating | -20°C ≤ Ta ≤ 70°C |
Maximum DC Input Voltage | Ui = 28 V |
Maximum Input Current | Ii = 93 mA |
Maximum Input Power | Pi = 650 mW |
Maximum Internal Capacitance | Ci = 8 nF |
Maximum Internal Inductance | Li = 0 mH |
Temperature range | Configurable from -20°C to 1000°C via optional USB adapter; pre-set to a choice of ranges between these limits (see Ordering) |
Output | 4 to 20 mA, Optional USB configuration tool and RS-485 network interface available |
Accuracy | ± 1°C or 1%, whichever is greater |
Repeatability | ± 0.5°C or 0.5%, whichever is greater |
Emissivity setting method | User configurable via optional modules |
Response time, t90 | 240 ms (90% response) |
Spectral range | 8 to 14 μm |
Supply voltage | 12 to 24 V DC ± 5% |
Maximum current draw | 25 mA |
Construction | Stainless Steel 316 |
Major dimensions | Ø 20 mm x length 150 mm (see Installation) |
Mounting | M20 x 1.5 mm thread, length 46 mm, supplied with two mounting nuts |
Cable length | 5 m, 10 m or 25 m as standard (custom lengths are also available) |
Weight with 5 m cable | 475 g |
Environmental rating | IP65 (NEMA 4) |
Ambient temperature range | 0°C to 70°C (Operating range) |
Ambient pressure range | 80 kPa (0.8 bar) to 110 kPa (1.1 bar) |
Relative humidity | Max. 95% non-condensing |
Customisation possibilities
You can remark the customisation in your quote
Productcode | |
---|---|
… |