LEX25
LEX25 Ex ia/ib certified thermocouple for zone 0, 1 and 2
Specifications
| ATEX certificate | DEKRA 17ATEX0123 X |
| IECEx execution | Ex ia IIC T6...T1 Ga |
| Ex ia/ib IIC T6...T1 Ga/Gb | |
| Ex ib IIC T6...T1 GB | |
| IECEx certificate | IECEx DEK 17.0046X |
| ATEX execution | II 1 G Ex ia IIC T6...T1 Ga |
| II 1/2 G Ex ia/ib IIC T6...T1 Ga/Gb | |
| II 2 G Ex ib IIC T6...T1 Gb | |
| Suitable for zone | 0, 1 and 2 |
| Ingress protection | IP65 / IEC529 |
| Ambient temp. range | -45°C...+80°C, this can be limited depending on the materials applied such as cables, connection heads, junction boxes and transmitters. |
| Construction | Mineral insulated ( MgO ) |
| Material | SS316 standard, other materials possible |
| Diameter | Customer to specify (0.25-12.7mm) |
| Length | Customer to specify |
| Isolated |
| Length | 45mm |
| Diameter | To suit cable diameter |
| Calibration | K, T, J, E, N, R, S, B, U or L |
| For duplex | KK, TT, JJ, EE, NN, RR, SS, BB, UU or LL |
| Accuracy | According to 60584-1 |
| Type of cable | PVC standard |
| Option | PUR, Silicon or PTFE insulated cable |
| Cable length | Customer to specify |
| This datasheet is purely indicative, build-up of model code may vary from this datasheet depending on chosen model or execution! |
Customisation possibilities
You can remark the customisation in your quote
| Productcode | LEX25 |
|---|---|
| Thermocouple calibration | … |
| Colourcode | … |
| Diameter in mm | … |
| Length "L" in mm | … |
| Length "K" in mm | … |