LV2004
LV2004 Vibration proof resistance thermometer
Specifications
Designed for Offshore and Marine use | |
Type approval | LLoyds Register Marine |
Series | LV2000 |
Stainless steel tube filled with Magnesium Oxide (MgO) | |
Material | Stainless steel 316 (1.4404) |
Insertion length | 150mm standard, other lengths possible |
Diameter | 6.0mm standard, optional 3.0, 4.5, 4.8 or 8.0mm |
1/4"BSP (G1/4") standard, other threads possible |
Small diameter sensors can break due to high vibrations, the use of a thermowell or pocket can be imperative, check with your engine manufacturer or consult factory. |
Heat and oil resistant armoured extension cable 250 °C | |
Cable length | 1000mm standard, other lengths possible |
Single or Duplex Pt100 | |
Accuracy | According IEC 60751 Cl. B, A or AA |
Style / Connection | 3-wire system standard, 4-wire system optional |
Testing | Tested 500 Vdc @ 20°C |
Insulation | Minimum 100 Mohm |
Design | Vibrationproof |
Temperature range | Standard -50/+150°C, optional up to 600°C |
Customisation possibilities
You can remark the customisation in your quote
Productcode | LV2004 |
---|---|
Sensor S or D | … |
Connection 3- or 4-wire | … |
Class B, A or AA | … |
Diameter "D" in mm | … |
Length "L" in mm | … |
Length "K" in mm | … |